Evaluation of a Real-Time Direct Volume Rendering System

Loading...
Thumbnail Image
Date
1996
Journal Title
Journal ISSN
Volume Title
Publisher
The Eurographics Association
Abstract
VIRIM, a real-time direct volume rendering system is evaluated for medical applications. Experiences concerning the hardware architecture are discussed. The issues are the flexibility of VIRIM, the restriction to two gradient components only, the duplication of the volume data sets on different modules, the size of the volume data set, the gray-value segmentation tool, and the support of algorithmic improvements like space- leaping, early ray-termination and others.It turned out that flexibility is the main benefit and absolutely necessary for VIRIM. Given this flexibility the application areas of real-time rendering systems increase dramatically: Most of the user requirements focus now not on visualization but on general volume data processing. The most serious botĀ­ tleneck of VIRIM is the limited volume memory that is inteĀ­ grated on the first prototype.
Description

        
@inproceedings{
10.2312:EGGH/EGGH96/121-131
, booktitle = {
Eurographics Workshop on Graphics Hardware
}, editor = {
Bengt-Olaf Schneider and Andreas Schilling
}, title = {{
Evaluation of a Real-Time Direct Volume Rendering System
}}, author = {
Boer, M. de
 and
Hesser, J.
 and
Gropl, A.
 and
Gunther, T.
 and
Poliwoda, C.
 and
Reinhart, C.
 and
Manner, R.
}, year = {
1996
}, publisher = {
The Eurographics Association
}, ISSN = {
-
}, ISBN = {
-
}, DOI = {
10.2312/EGGH/EGGH96/121-131
} }
Citation